Ethylenediamine

CAS RN:107-15-3

Cleanup Methods

1. Remove all ignition sources. 2. Ventilate area of spill or leak. 3. If in the liq form, absorb on paper towels. Evaporate in a safe place (such as a fume hood). Allow sufficient time for evaporating vapors to completely clear the hood ductwork. Burn the paper in a suitable location away from combustible materials. Large quantities can be collected and atomized in a suitable combustion chamber equipped with an appropriate effluent gas cleaning device. ... 4. If in the solid form, collect, allow to melt, and dispose of the liq as above.
Overspread /spill with/ sufficient sodium bisulfate and sprinkle water.
Find more information on this substance at: Hazardous Substances Data Bank , TOXNET , PubMed