Piperidine

CAS RN:110-89-4

Storage Conditions

Fireproof. Separated from strong oxidants, acids, incompatible materials See Chemical Dangers.
Store in tightly closed containers in a cool, well vented area away form oxidizers. Where possible, automatically pump liquid from drums or other storage containers to process containers. Sources of ignition such as smoking and open flames are prohibited where this chemical is handled, used, or stored. Metal containers involving the transfer of 5 gallons or more of this chemical should be grounded and bonded. Drums must be equipped with self-closing valves, pressure vacuum bungs, and flame arresters. Use only non-sparking tools and equipment, especially when opening and closing containers of this chemical. Whenever this chemical is used, handled, manufactured, or stored, use explosion-proof electrical equipment and fittings.
Find more information on this substance at: Hazardous Substances Data Bank , TOXNET , PubMed