Boron Trifluoride

CAS RN:7637-07-2

Cleanup Methods

Approach release from upwind. Stop or control the leak, if this can be done without undue risk. Use water spray to cool and disperse vapors and protect personnel. Avoid wetting leak or spill area. Releases may require isolation or evacuation.

Evacuate danger area! Consult an expert! Ventilation. NEVER direct water jet on liquid. Remove fumes with fine water spray (extra personal protection: complete protective clothing including self-contained breathing apparatus).

Ventilate area of leak to disperse the gas. Stop flow of gas. If source of leak is cylinder and leak cannot be stopped in place, remove ... to safe place in open air, and repair leak or allow cylinder to empty.

Find more information on this substance at: Hazardous Substances Data Bank , TOXMAP , TOXNET , PubMed