Stibine

CAS RN:7803-52-3

Fire Fighting Procedures

Stop flow of gas before extinguishing fire. Approach fire from upwind to avoid hazardous vapors & toxic decomp products. Fight fire from protected location or maximum possible distance. Explosive decomp may occur under fire conditions. Use flooding quantities of water as spray. DO NOT use halogenated extinguishing agents. Use water spray to keep fire-exposed containers cool.
Find more information on this substance at: Hazardous Substances Data Bank , TOXNET , PubMed