Propionic Anhydride

CAS RN: 123-62-6

Cleanup Methods

Spill or leak procedures: Use water spray to cool and disperse vapors, protect personnel, and dilute spills to form nonflammable mixtures. Control runoff and isolate discharged material for proper disposal. Neutralize spill and washings with soda ash or lime.
Environmental considerations: Land spill: Dig a pit, pond, lagoon, or holding area to contain liquid or solid material /SRP: If time permits, pits, ponds, lagoons, soak holes, or holding areas should be sealed with an impermeable flexible membrane liner./ Dike surface flow using soil, sand bags, foamed polyurethane, or foamed concrete. Absorb bulk liquid with fly ash or cement powder.
Environmental considerations: Water spill: Neutralize with agricultural lime (Cao), crushed limestone (CaCO3), or sodium bicarbonate (NaHCO3). If dissolved, in region of 10 ppm or greater concentration, apply activated carbon at ten times the spilled amount. Use mechanical dredges or lifts to remove immobilized masses of pollutants and precipitates.
Environmental considerations: Air spill: Apply water spray or mist to knock down vapors.Vapor knockdown water is corrosive or toxic and should be diked for containment.