Chloroform

CAS RN: 67-66-3

Storage Conditions

Keep in tightly closed containers; storage code: LI
Store in cool, dry, well-ventilated location. Separate from strong alkalis and strong mineral acids.
Glass containers should be dark green or amber. Technical-grade chloroform can be stored in lead-lined or mild steel containers of all-welded construction. When storage vessels are made of unlined steel, precautions are needed to prevent the entry of moisture.
Preserve ... at a temp not exceeding 30 deg C.
PRECAUTIONS FOR "CARCINOGENS": Storage site should be as close as practicable to lab in which carcinogens are to be used, so that only small quantities required for ... expt need to be carried. Carcinogens should be kept in only one section of cupboard, an explosion-proof refrigerator or freezer (depending on chemicophysical properties ...) that bears appropriate label. An inventory ... should be kept, showing quantity of carcinogen & date it was acquired ... Facilities for dispensing ... should be contiguous to storage area. /Chemical Carcinogens/
Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Storage class (TRGS 510): 6.1D: Non-combustible, acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects
Find more information on this substance at: PubChem, PubMed