Carbon monoxide

CAS RN: 630-08-0

Fire Fighting Procedures

Stop flow of gas before extinguishing fire. Use water spray to keep fire-exposed containers cool. Fire situation may require evacuation.
Use powder or carbon dioxide.
If material on fire or involved in fire: Do not extinguish fire unless flow can be stopped. Use water in flooding quantities as fog. Cool all affected containers with flooding quantities of water. Apply water from as far a distance as possible.
Let fire burn; shut off flow of gas and cool adjacent exposures with water. Extinguish (only if wearing self-contained breathing apparatus) with dry chemicals or carbon dioxide.
Find more information on this substance at: PubChem, PubMed