Methyl isobutyl ketone

CAS RN: 108-10-1

Fire Fighting Procedures

Suitable extinguishing media: Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Advice for firefighters: Wear self contained breathing apparatus for fire fighting if necessary.
Fire extinguishers containing carbon dioxide, dry powder, or foam are recommended. Flashback along a vapor trail may occur. Water should not be used, since this may cause the fire to spread, though a water spray can be used to cool containers.
Use water spray, dry chemical, "alcohol resistance" foam, or carbon dioxide. Water may be ineffective. Ue water spray to keep fire-exposed containers cool.
Find more information on this substance at: PubChem, PubMed