Lead Acetate

CAS RN: 301-04-2

Protective Equip. / Clothing

Wear protective gloves and clothing to prevent any reasonable probability of skin contact ... Contact lenses should not be worn when working with this chemical. Wear dust-proof chemical goggles and face shield unless full facepiece respiratory protection is worn ... Wash immediately with soap when skin is wet or contaminated. Provide emergency showers and eyewash.
PRECAUTIONS FOR "CARCINOGENS": ... Dispensers of liq detergent /should be available/ ... Safety pipettes should be used for all pipetting. ... In animal laboratory, personnel should ... wear protective suits (preferably disposable, one-piece & close-fitting at ankles & wrists), gloves, hair covering & overshoes ... In chemical laboratory, gloves & gowns should always be worn ... however, gloves should not be assumed to provide full protection. Carefully fitted masks or respirators may be necessary when working with particulates or gases, & disposable plastic aprons might provide addnl protection ... Gowns ... /should be/ of distinctive color, this is a reminder that they are not to be worn outside the laboratory. /Chemical Carcinogens/
Wear appropriate personal protective clothing to prevent skin contact. /Lead/
Wear appropriate eye protection to prevent eye contact. /Lead/
Respirator Recommendations: Up to 0.5 mg/cu m. /Lead/
Assigned Protection Factor (APF) Respirator Recommendation
APF = 10 Any air-purifying respirator with an N100, R100, or P100 filter (including N100, R100, and P100 filtering facepieces) except quarter-mask respirators.
APF = 10 Any supplied-air respirator.
Respirator Recommendations: Up to 1.25 mg/cu m. /Lead/
Assigned Protection Factor (APF) Respirator Recommendation
APF = 25 Any supplied-air respirator operated in a continuous-flow mode.
APF = 25 Any powered, air-purifying respirator with a high-efficiency particulate filter.
Respirator Recommendations: Up to 2.5 mg/cu m. /Lead/
Assigned Protection Factor (APF) Respirator Recommendation
APF = 50 Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
APF = 50 Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode.
APF = 50 Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter.
APF = 50 Any self-contained breathing apparatus with a full facepiece.
APF = 50 Any supplied-air respirator with a full facepiece.
Respirator Recommendations: Up to 50 mg/cu m. /Lead/
Assigned Protection Factor (APF) Respirator Recommendation
APF = 1000 Any supplied-air respirator operated in a pressure-demand or other positive-pressure mode.
Respirator Recommendations: Up to 100 mg/cu m. /Lead/
Assigned Protection Factor (APF) Respirator Recommendation
APF = 2000 Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode.
Respirator Recommendations: Emergency or planned entry into unknown concentrations or IDLH conditions: /Lead/
Assigned Protection Factor (APF) Respirator Recommendation
APF = 10,000 Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode.
APF = 10,000 Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus.
Respirator Recommendations: Escape conditions: /Lead/
Assigned Protection Factor (APF) Respirator Recommendation
APF = 50 Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter. /Any appropriate escape-type, self-contained breathing apparatus.